BW Technologies Factory Default Alarm Settings
Modified on: Mon, 25 Nov, 2013 at 10:29 PM
Factory Default Alarm Settings:
| GAS |
Low |
High |
TWA |
STEL |
| H2S |
10ppm |
15ppm |
10ppm |
15ppm |
| SO2 |
2ppm |
5ppm |
2ppm |
5ppm |
| HCN |
4.7ppm |
10ppm |
4.7ppm |
10ppm |
| CO |
35ppm |
200ppm |
35ppm |
50ppm |
| CI2 |
0.5ppm |
1.0ppm |
0.5ppm |
1.0ppm |
| NO2 |
2ppm |
5ppm |
2ppm |
5ppm |
| NO |
25ppm |
25ppm |
25ppm |
25ppm |
| NH3 |
25ppm |
50ppm |
25ppm |
50ppm |
| PH3 |
0.3ppm |
1.0ppm |
0.3ppm |
1.0ppm |
| ETO |
1ppm |
5ppm |
1ppm |
5ppm |
| CLO2 |
0.1ppm |
0.3ppm |
0.1ppm |
0.3ppm |
| O3 |
0.1ppm |
0.2ppm |
0.1.ppm |
0.1ppm |
| CO2 |
5,000ppm |
30,000ppm |
5,000ppm |
30,000ppm |
| VOC |
50ppm |
100ppm |
50ppm |
100ppm |
| O2 |
19.5% Vol. |
23.5% Vol. |
N/A |
N/A |
| Combustible |
10% LEL |
20% LEL |
N/A |
N/A |