BW Technologies Factory Default Alarm Settings
Modified on: Mon, 25 Nov, 2013 at 10:29 PM
Factory Default Alarm Settings:
GAS |
Low |
High |
TWA |
STEL |
H2S |
10ppm |
15ppm |
10ppm |
15ppm |
SO2 |
2ppm |
5ppm |
2ppm |
5ppm |
HCN |
4.7ppm |
10ppm |
4.7ppm |
10ppm |
CO |
35ppm |
200ppm |
35ppm |
50ppm |
CI2 |
0.5ppm |
1.0ppm |
0.5ppm |
1.0ppm |
NO2 |
2ppm |
5ppm |
2ppm |
5ppm |
NO |
25ppm |
25ppm |
25ppm |
25ppm |
NH3 |
25ppm |
50ppm |
25ppm |
50ppm |
PH3 |
0.3ppm |
1.0ppm |
0.3ppm |
1.0ppm |
ETO |
1ppm |
5ppm |
1ppm |
5ppm |
CLO2 |
0.1ppm |
0.3ppm |
0.1ppm |
0.3ppm |
O3 |
0.1ppm |
0.2ppm |
0.1.ppm |
0.1ppm |
CO2 |
5,000ppm |
30,000ppm |
5,000ppm |
30,000ppm |
VOC |
50ppm |
100ppm |
50ppm |
100ppm |
O2 |
19.5% Vol. |
23.5% Vol. |
N/A |
N/A |
Combustible |
10% LEL |
20% LEL |
N/A |
N/A |
Did you find it helpful?
Yes
No
Send feedback Sorry we couldn't be helpful. Help us improve this article with your feedback.